Sample report

A fictitious structure, used to show what SpanLink produces. The BIN, structure number, road, coordinates and personnel are invented and this is not a record of any real inspection.

BrM entry sheet

Bridge Inspection Report

SpanLink

Bridge Identification Number (BIN)
B-019427
Structure Number (STR)
S-0442-11
Road Name
County Road 27 over Flint Creek
Inspection Type (B.IE.01)
2 - Routine
Inspection Date (B.IE.02)
September 11th, 2026
Next Inspection Due (B.IE.06)
September 11th, 2028
Inspector
A. Inspector
Team Leader (B.IE.04)
J. Team Leader
Certification Number
AL-00000
Location (B.L.05 / B.L.06)
34.512440° N, 86.983110° W
Site Conditions
Clear, light wind, 74°F

Structure

Number of Spans
2
Overall Length
156 ft
Span Lengths
78 / 78 ft
Deck Width
34 ft
Superstructure
5 girders per span
Supports
1 interior pier, 2 abutments

SNBI Condition Ratings

Deck (B.C.01)
6
Satisfactory
Superstructure (B.C.02)
5
Fair
Substructure (B.C.03)
5
Fair

Field Notes

Routine inspection of a two-span prestressed concrete girder bridge carrying County Road 27 over Flint Creek. Deck is in satisfactory condition with transverse cracking and one delaminated area in the northbound wheel path. Span 1 girder 3 has a spall with two exposed strands at the bottom flange near midspan; no measurable section loss was found and the member was sounded and measured. Pier 1 cap is spalled beneath the girder 5 bearing with exposed reinforcing showing section loss. Channel is stable with no evidence of active scour at either substructure unit.

Element Condition Summary

ElemElementUnitTotalCS-1CS-2CS-3CS-4
12Reinforced Concrete DeckSF2652242123100
109Prestressed Concrete Open Girder / BeamLF390378660
215Reinforced Concrete AbutmentLF3426800
234Reinforced Concrete Pier CapLF3425090
205Reinforced Concrete ColumnEA32100

Condition state quantities are reported in each element's own unit. CS-1 is the quantity with no reported defect; CS-1 through CS-4 sum to the element total.

AASHTOWare BrM
Ready for BrM, waiting on AASHTOWare

The integration is built and your subscription is configured. AASHTOWare has withdrawn the BrM API Lab and says a replacement is coming, so there is no endpoint to sync to yet. Nothing is lost: inspections are kept in full and will sync once the new API is available.

What is already built

  • Element condition states map straight onto BrM's own quantities, CS-1 through CS-4.
  • Inspections queue offline and sync when a signal returns.
  • Quantities are checked against the element total before anything is sent, so BrM has nothing to reject.

Your inspections are saved in full and export as a PDF or CSV in the meantime.

Change Since Last Cycle
Compared against the 2 - Routine inspection of September 5th, 2024 by A. Inspector.
Elements deteriorating
4
Newly in CS-4
0
SNBI Condition Ratings
Deck
7 → 6
Superstructure
6 → 5
Substructure
5 → 5
ElementChangeDefected thenDefected nowWhat moved
12 Reinforced Concrete DeckDeteriorated92 SF231 SF139 SF more defected than last cycle.
109 Prestressed Concrete Open Girder / BeamDeteriorated6 LF12 LF6 LF more defected than last cycle.
234 Reinforced Concrete Pier CapDeteriorated4 LF9 LF5 LF more defected than last cycle.
205 Reinforced Concrete ColumnDeteriorated0 EA1 EA1 EA more defected than last cycle.
215 Reinforced Concrete AbutmentUnchanged8 LF8 LFNo change in defected quantity.

Assembly Sketches

Span 1 - Deck (Deck)

Notes: Transverse cracking through the northbound wheel path, heaviest over the pier. Efflorescence on the underside at the same location.

Full Deck Assembly Area
1080 · CS2 (46)
1130 · CS2 (120)
1120 · CS2 (30)
Defect TypeCondition StateTotal Quantity
1080 - Delamination / Spall / Patched AreaCS-246
1120 - Efflorescence / Rust StainingCS-230
1130 - Cracking (RC and Other)CS-2120

Span 2 - Deck (Deck)

Notes: Sound throughout. No delamination detected on sounding.

Full Deck Assembly Area
1130 · CS2 (35)
Defect TypeCondition StateTotal Quantity
1130 - Cracking (RC and Other)CS-235

Span 1 - Girders (Girders)

Notes: Girder 3 shows a spall with exposed strand at the bottom flange near midspan. Recommend follow-up.

Girder 1CS-1 Default Zone
Girder 2CS-1 Default Zone
Girder 3CS-1 Default Zone
Girder 4CS-1 Default Zone
Girder 5CS-1 Default Zone
1080 · CS3 (4)
1100 · CS3 (2)
1110 · CS2 (6)
Defect TypeCondition StateTotal Quantity
1080 - Delamination / Spall / Patched AreaCS-34
1100 - Exposed PrestressingCS-32
1110 - Cracking (PSC)CS-26

Abutment 1 (Abutments)

Notes: Minor map cracking on the exposed face. Backwall sound.

Abutment Wall Face
1130 · CS2 (8)
Defect TypeCondition StateTotal Quantity
1130 - Cracking (RC and Other)CS-28

Pier 1 - Pier Caps (Pier Caps)

Notes: Spalling at the east end of the cap beneath the girder 5 bearing, with exposed reinforcing.

Pier Cap Beam
1080 · CS3 (6)
1090 · CS3 (3)
Defect TypeCondition StateTotal Quantity
1080 - Delamination / Spall / Patched AreaCS-36
1090 - Exposed RebarCS-33

Pier 1 - Columns (Columns)

Notes: Column 2 shows efflorescence along a vertical crack. Columns 1 and 3 sound.

Column 1
Column 2
Column 3
1120 · CS2 (1)
Defect TypeCondition StateTotal Quantity
1120 - Efflorescence / Rust StainingCS-21

Channel Soundings

Channel Cross-Section

Benchmark: TOP OF PARAPET WALL · Direction: N

Deepest reading 13.4 ft at station 30.

Total Inspection Defect Summary
Consolidated defects from all assembly drawings.
Assembly ElementDefect TypeCondition StateTotal Quantity
AbutmentsCrackCS-28
ColumnsEfflorescenceCS-21
DeckCrackCS-2155
EfflorescenceCS-230
Spall/DelamCS-246
GirdersCrackCS-26
Exposed RebarCS-32
Spall/DelamCS-34
Pier CapsExposed RebarCS-33
Spall/DelamCS-36

Certification

This inspection was performed in accordance with the National Bridge Inspection Standards (23 CFR 650 Subpart C) and recorded per the Specifications for the National Bridge Inventory. Element condition states follow the AASHTO Manual for Bridge Element Inspection.

J. Team Leader

Team Leader · Cert. AL-00000

A. Inspector

Inspector · Sep 11, 2026

Produced by SpanLink · sample data

BrM Entry Sheet

Open this inspection in BrM (Inspection › Condition) and type straight down this page. It follows BrM's screen in order.

Bridge ID
B-019427
Inspection
09/11/2026

Ready for BrM

Every element balances and every rating is chosen.

1Condition Ratings

Deck Condition Rating (B.C.01)

6 Satisfactory

Superstructure Condition Rating (B.C.02)

5 Fair

Substructure Condition Rating (B.C.03)

5 Fair

Culvert Condition Rating (B.C.04)

N Not Applicable

Bridge Condition Classification (B.C.12)

BrM calculates this — should show F Fair

Lowest Condition Rating Code (B.C.13)

BrM calculates this — should show 5

Bridge Railing Condition Rating (B.C.05)

7 Good

Bridge Railing Transitions Condition Rating (B.C.06)

6 Satisfactory

Bridge Bearings Condition Rating (B.C.07)

6 Satisfactory

Bridge Joints Condition Rating (B.C.08)

5 Fair

Channel Condition Rating (B.C.09)

7 Good

Channel Protection Condition Rating (B.C.10)

7 Good

2Element Conditions

Type the bold numbers. CS 1 is greyed because BrM calculates it; check that BrM shows the same.

IDNameTotal QtyUnitsCS 1CS 2CS 3CS 4
12Reinforced Concrete Deck2652sq.ft242123100Update in BrM
1080Delamination / Spall / Patched Area46sq.ft04600
1120Efflorescence / Rust Staining30sq.ft03000
1130Cracking (RC and Other)155sq.ft015500
109Prestressed Concrete Open Girder / Beam390ft378660Update in BrM
1080Delamination / Spall / Patched Area4ft0040
1100Exposed Prestressing2ft0020
1110Cracking (PSC)6ft0600
205Reinforced Concrete Column3each2100Update in BrM
1120Efflorescence / Rust Staining1each0100
215Reinforced Concrete Abutment34ft26800Unchanged: skip
1130Cracking (RC and Other)8ft0800
234Reinforced Concrete Pier Cap34ft25090Update in BrM
1080Delamination / Spall / Patched Area6ft0060
1090Exposed Rebar3ft0030

3Notes

Inspection Note (B.IE.11)

Routine inspection of a two-span prestressed concrete girder bridge carrying County Road 27 over Flint Creek. Deck is in satisfactory condition with transverse cracking and one delaminated area in the northbound wheel path. Span 1 girder 3 has a spall with two exposed strands at the bottom flange near midspan; no measurable section loss was found and the member was sounded and measured. Pier 1 cap is spalled beneath the girder 5 bearing with exposed reinforcing showing section loss. Channel is stable with no evidence of active scour at either substructure unit.

Notes from your sketches, for BrM's Agency Inspection Notes or wherever your agency keeps element notes.

Abutment 1

Minor map cracking on the exposed face. Backwall sound.

Pier 1 - Columns

Column 2 shows efflorescence along a vertical crack. Columns 1 and 3 sound.

Pier 1 - Pier Caps

Spalling at the east end of the cap beneath the girder 5 bearing, with exposed reinforcing.

Span 1 - Deck

Transverse cracking through the northbound wheel path, heaviest over the pier. Efflorescence on the underside at the same location.

Span 1 - Girders

Girder 3 shows a spall with exposed strand at the bottom flange near midspan. Recommend follow-up.

Span 2 - Deck

Sound throughout. No delamination detected on sounding.